Fort Pierce--Maximum Gas Consumtion for Planning Purposes

From
Mike Coleman mike.coleman@enron.com
To
V. Charles Weldon
Cc
Mark Breese, Ruth Concannon, Mathew Gimble, Darrell Stovall, Jeffrey Keenan, douglas.ottens@enron.com, Jennifer Bagwell
Bcc
Mark Breese, Ruth Concannon, Mathew Gimble, Darrell Stovall, Jeffrey Keenan, douglas.ottens@enron.com, Jennifer Bagwell
Date
Wed, 23 May 2001 14:09:56 -0700 (PDT)
Charlie,

The new plant max consumption for planning purposes should be set at 2,490 mmBtu/hr HHV.  In addition to this it is estimated that the existing Frame 5 may require 335 mmBtur/hr HHV, or a total of 2,825 mmBtu/hr HHV.

The plant consumption is based on the maximum combustion turbine requirement, plus a 5% margin, plus duct burning requirement.  This should be adequate as a conservative maximum case.

Please let me know if you have any questions.