31 Jul 2001, 18:35 UTC
RE: Conversions
- From
- Rajneesh Salhotra rajneesh.salhotra@enron.com
- To
- Jason Kaniss
- Date
- Tue, 31 Jul 2001 11:35:27 -0700 (PDT)
Jason, I am not sure whether you really require the number of tons/ mmBtu needed to fire a plant. What we really need is the cost of coal and gas in terms of $/MwH (so that you can calculate the difference between power (quoted in $/MwH) and the fuel). For that, the conversions will be as follows: Coal The price for coal will be quoted in $x/ Ton. To convert it to $/MwH, you will have to do the following: Assumptions: Heat Content 12,000 Btu/Lbs Heat Rate 11,000 Btu/KwH Transportation Cost $3 /Ton Cost ($/MwH) ((x+3)*11,000)/(2*12,000) Gas The price for coal will be quoted in $y/ mmBtu. To convert it to $/MwH, you will have to do the following: Assumptions: Heat Rate 10,000 Btu/KwH Cost ($/MwH) (y*10,000)/1,000 If possible, try to put all the assumptions as inputs in the first sheet to allow changes. Give me a call if you need any further clarification. Trevor, I hope the above conversions are in order. Rajneesh Salhotra _____________________________________________________ Rajneesh Salhotra Coal and Emissions Trading Enron Global Markets 713.853.6764
Quoted or forwarded from earlier messages
-----Original Message----- From: Kaniss, Jason Sent: Tuesday, July 31, 2001 1:09 PM To: Salhotra, Rajneesh Subject: Conversions Raj, Do you know how I can convert the following. Number of Tons of Coal it takes to fire a plant. Number of MMBtus of Gas it takes to fire a plant. I need those conversions in order to do the calculations for the Sip Call. (Unless I am looking at it wrong, and I don't need them.) Jason