15 May 2002, 07:40 UTC
Calculating "Vestas Availability"
- From
- Hollis Kimbrough hollis.kimbrough@enron.com
- Date
- Wed, 15 May 2002 00:40:00 -0700 (PDT)
Guys, In an earlier e-mail Ben made the statement: "Have you been able to determine what these numbers would look like using Vestas' definition of availability: Hours of Wind Turbine in Operation mode X 100 / Hours of Grid in Operation Mode." We now need to develop a methodology to calculate the Vestas definition using VisuPro data. I think this boils down to: Vestas Avail = (SOT+WOT+EST+RT+MT)/(ST-LOT) Where: SOT = System Okay Time EST = External Stop Time WOT = Weather Out Time LOT = Line Out Time DT = Down Time RT = Repair Time MT = Maintenance Time ST = SOT+EST+WOT+LOT+DT+RT+MT This calculation is based on an operating assumption that the current day machines are placed into "pause" mode during maintenance and repair time. As a result the availability counters will continue to increment even when the turbine is being serviced. Let's get together and discuss, Hollis