20% is absolute low on surge margin for this unit. IF IT GOES BELOW 20% RAISE THE SUCTION SET POINT!!! The unit will lock into minimum RPM when surge margin hits 15% and will not unlock until surge margin gets above 20%. Recommended to change set point in 10# increments when lowering set point so surge margin can be better monitored. Alarm limits have changed.
LO - 25
LO LO - 20
Thanks
Bart