5 May 1999, 12:27 UTC
Results of the PG&E Filter Separator Cleaning
- From
- Larry Campbell larry.campbell@enron.com
- Date
- Wed, 5 May 1999 05:27:00 -0700 (PDT)
Just a short message to apprise everyone of the cleaning results performed on the filter separator from the Transwestern M/S. Wipe tests taken of the interrior portions of the separator prior to cleaning revealed PCB results of: 360, 500 and 520 microgram. This was not a standard wipe taken of a specific area. These wipes were taken over large areas to determine presence/absence of PCB's within the separator. After the cleaning operation was completed, three wipe samples were taken of the interrior portions of the separator. All results showed non detect at less than 1.0 microgram. I feel we can be fairly certain that the separator is free of residual PCBs. Jeff, would you pass this information on to your counterpart for PG&E?