12 Oct 2001, 16:33 UTC
Northern v. ONEOK/Bushton Measurement Issue/Chromatograph malfunction 9/19-10/11
- From
- Britt Davis britt.davis@enron.com
- Cc
- Gary E. Anderson, Robert Benningfield, Lynn Blair, John Buchanan, Kenneth Cessac, Mary Darveaux, Rick Dietz, David Gaines, Charlie Graham, Don Hawkins, Steven January, Rick Kile
- Bcc
- Gary E. Anderson, Robert Benningfield, Lynn Blair, John Buchanan, Kenneth Cessac, Mary Darveaux, Rick Dietz, David Gaines, Charlie Graham, Don Hawkins, Steven January, Rick Kile
- Date
- Fri, 12 Oct 2001 09:33:24 -0700 (PDT)
Ken Cessac reported to me today concerning a problem with Northern's chromatograph at the Bushton Plant that occurred on 9/19 after a routine annual replacement of calibration gas by ETS, and that was fixed yesterday, although Ken needs to review the fix. In a nutshell, the problem appears likely to have caused the volumes to be off for the period of time at issue; it is yet to be determined whether the Btu's per MMBtu will be off. Angela Mendez apparently caught this when certain values started repeating themselves. I am told that a similar problem was experienced when the chromatograph was first installed years ago, but thought to have been fixed. Once Ken has finished his review and I have spoken with Rick Kile, we can draft the appropriate letter. I will continue to keep you advised. Britt