21 Aug 2000, 21:43 UTC
Enron Facilities in the Houston Area
- From
- Marc Phillips marc.phillips@enron.com
- Date
- Mon, 21 Aug 2000 14:43:00 -0700 (PDT)
The MTBE plant, located on 70 acres of land in Morgan's Point, can produce 17,000 barrels per day of MTBE. Feedstocks to the plant to produce the MTBE are methanol from Enron's methanol plant and normal butane from the Mt. Belvieu underground storage facility. The emission sources at this facility are authorized under Texas Natural Resource Conservation Commission (TNRCC) air permits and authorizations (e.g., Standard Exemptions) and are not "grandfathered" emission sources. Grandfathered emissions sources are sources installed in Texas before September, 1971 (that predate the Texas Clean Air Act) and are often uncontrolled. The major sources of NOx emissions at this plant are two boilers, an oleflex heater, and three hot oil heaters. All are currently controlled with low NOx burners, but will require more combustion controls and Selective Catalytic Reduction (SCR) to attain the strict limits in the proposed Houston non-attainment regulations. The proposed limits are 0.01 pounds of NOx per MMbtu for the two boilers and oleflex heater, and 0.015 pounds of NOx per MMbtu for the smaller hot oil heaters. One third of the reductions must be attained by the end of 2002, two thirds by the end of 2003, and all reductions must be completed (or emission credits purchased) by December 31, 2004. Major Volatile Organic Compound (VOC) emission sources at this facility include storage tanks (controlled with floating roofs) and loading facilities. The methanol plant, located on 20 acres in Pasadena, can produce 125,000,000 gallons of methanol per year. Feedstocks to the plant to produce methanol are natural gas and oxygen. Most of the emission sources at this facility are authorized under TNRCC air permits and Standard Exemptions, but some predate the Texas Clean Air Act and are grandfathered. The major sources of NOx emissions at this plant are a reformer (heater) and three natural gas-fired reciprocating engines. The reformer is currently controlled with low NOx burners, but will require more combustion controls and Selective Catalytic Reduction (SCR) to attain the strict limit of 0.01 pounds of NOx per MMbtu in the proposed Houston non-attainment regulations. The proposed limit for the engines (currently uncontrolled) is 0.017 grams per horsepower-hour. Although combustion controls and SCR are possible control methods to attain this strict limit, they are unproven on engines, and it is likely that the engines will need to be replaced with electric motors. One third of the reductions must be attained by the end of 2002, two thirds by the end of 2003, and all reductions must be completed (or credits purchased) by December 31, 2004. Major VOC emissions sources at this facility include storage tanks (controlled with scrubbers) and loading facilities. The Bammel gas storage facility is located on Kuykendahl Road in north Houston and is used for the underground storage of natural gas. The 15 natural gas-fired engines at this facility were replaced with electric motors in 1999. The estimated reductions of emissions by the replacements at this facility were 1,254 tons/year of NOx and 42 tons per year of VOC. Most of the NOx credits have been sold to other companies under TNRCC,s current trading program, which is not a cap and trade program. The remaining minimal emissions at this site are from the glycol dehydrators (NOx and VOC), and storage tanks (VOC). The VOC emissions from the dehydrators are already controlled with incinerators under current TNRCC regulations. The 1999 emissions from the chemical plants as indicated in Enron,s EH&S Annual Report are 2,822 tons per year of NOx, 823.7 tons per year of VOC, and 195 tons per year of Carbon Monoxide. Most of the NOx emissions are from the uncontrolled engines at the methanol plant. The Cost Estimate for the installation of combustion controls and SCR, and replacement of the engines at the chemical plants is $30 to $40 million.